RObust Mini direct flow reverse osmosis system
$17.38
$22.07
DescriptionParameterFlow capacity 55-60 L/hWater consumption 55–60 L/hWaste wate110-120 L/hFeed water pressure 2-5 barOperating water pressure 5-7 barElectrical requirement 100-240 V, 50-60 HzPower consumption 0.08 kWSystem ComponentAssembled filterPre–filter and post–filterReverse osmosis membranesFeed adapterDrain saddleInstallation fitting setSet of tubesService wrenchSource Water RequirementpH 6.5–8.5Total dissolved solids (TDS) ≤1000 ppmHardness <500 ppm CaCO₃Chlorine ≤0.5 ppmIron ≤0.3 ppmManganese ≤0.05 ppmChemical oxygen demand ≤5 ppm O₂Total microbial count ≤100 CFU/mLColiform index NoneServiceThe RObust Mini direct flow reverse osmosis filter is designed for cold water purification only.Pressure monitoring There are no pressure gauges in the RObust Mini product; they need to be installed additionally to check the pressure in the system.Pre-filtration cartridgesReplace pre-filters after 8,000 liters of water filtration or at least every 3 months.If the pressure after the pre-filters drops below 1 bar, the cartridges may be clogged.Delaying replacement may damage or reduce the lifespan of the membrane.Reverse osmosis membrane With a significant drop in system performance, replacement of reverse osmosis membranes is required. Replace after filtering 24,000 liters or at least once per year if filtration speed decreases.Post-filtration cartridge Replace if taste deteriorates or odor appears, after 8,000 liters or at least every 3 months.Downtime maintenance If unused for over 2 weeks, disinfect before resuming use (procedure in the user manual).VideoDownloadsManual for Ecosoft RObust reverse osmosis systemEcosoft RObust Mini technical data sheet
Professional Filters